10MW 20MW Fiber Testing Tools Visual Fault Detector 30MW Black Leather Sheath
Method of use
1. Screw the end cap from the pen, the battery will be prepared into the pen, battery cathode to the end cap, the positive on the pen body is positive;(note: please do not turn pen and pencil tail into the battery)
2. Put the pen and pencil body connection installed, open the dust cap, press the control switch one time, observe the interface has a red light, luminous tube on at the same time;(note don't eyes were light interface, so as not to damage the eye)
3. Press the control switch again, observe the light into a pulse mode, the indicator light-emitting tube and out of sync pulse light;(pulse frequency in 2-3 hz or 9 hz)
4. Press the control switch again, light source closed, no light output, at the same time indicator light pipe out;(switch mode to: continuous - pulse - closed - continuous cycle mode)
5. When detecting insert tested optical fiber optical interface, press the control switch at the same time, choose the output light work mode (continuous or pulse);
6. After use, build the dust cap, do not use for a long time, please take out the battery, in order to avoid battery rot, damage the light source.
Maintenance and matters needing attention
Model | HCW 650-2S | ||||
Central wavelength | 650nm±10nm (635nm is available on request) | ||||
Emitter type | FP-LD | ||||
Output power | 5mw | ||||
Laser Range | ≥5km | ||||
Optical connector | 2.5mm universal connector, for 1.25mm connectors, FC (Male)-LC. (Female) convertor can be provided on request | ||||
Operating mode | Both CW and Pulse available | ||||
Pulse frequency | 2Hz to 3Hz / 9Hz | ||||
Power supply | 2AA alkaline batteries | ||||
Battery | LR6 AA alkaline battery | ||||
Operating temperature | -20°C to 60°C | ||||
Storage temperature | -40°C to 85°C | ||||
Dimension | 25 x 195mm | ||||
Weight | 165g (without battery) |